Difficulty

Moderate

Steps

9

Time Required

                          10 - 15 minutes            

Sections

2

  • Brewer Handle
  • 4 steps
  • Puncture Needle
  • 5 steps

Flags

0

  • BackKeurig B70 Platinum

  • Full Screen

  • Options

  • History

  • Save to Favorites

  • Download PDF

  • Edit

  • Translate

  • Get Shareable Link

  • Embed This Guide

  • Notify Me of Changes

  • Stop Notifications

Introduction

What you need

Step 1

              Brewer Handle               
  • Turn off and unplug the Keurig before starting.
  • Lay the Keurig on its back and open the lid.
  • Using a Phillips #2 screwdriver, remove the two 21.0 mm screws.
  • Be careful when removing the screws. There is a sharp puncture needle!
  • You may need to use tweezers to get the screws out.

Turn off and unplug the Keurig before starting.

Lay the Keurig on its back and open the lid.

Using a Phillips #2 screwdriver, remove the two 21.0 mm screws.

Be careful when removing the screws. There is a sharp puncture needle!

You may need to use tweezers to get the screws out.

1024

Step 2

  • Using a T15 Torx screwdriver, remove the two 29.0 mm screws on each ends of the handle.

Using a T15 Torx screwdriver, remove the two 29.0 mm screws on each ends of the handle.

Step 3

  • Lift and pull the black plastic cover away from the Keurig.

Lift and pull the black plastic cover away from the Keurig.

Step 4

  • Push the handle back and upward to detach it from the Keurig.

Push the handle back and upward to detach it from the Keurig.

Step 5

              Puncture Needle               
  • Using a Phillips #0 screwdriver, remove the two 7.0 mm screws located on the sides of the tube near the puncture needle.

Using a Phillips #0 screwdriver, remove the two 7.0 mm screws located on the sides of the tube near the puncture needle.

Step 6

  • Using both hands, pull the puncture needle tube and the Keurig tube apart to disconnect the tubes.
  • Don’t be afraid to pull hard! The tubes are tightly connected.

Using both hands, pull the puncture needle tube and the Keurig tube apart to disconnect the tubes.

Don’t be afraid to pull hard! The tubes are tightly connected.

Step 7

  • Slide the black plastic ring, which holds the puncture needle tube down, off of the tube.

Slide the black plastic ring, which holds the puncture needle tube down, off of the tube.

Step 8

  • Using a Phillips #2 screwdriver, remove the two 9.0 mm screws next to the detached tube.
  • Hold on to the puncture needle when removing the screws to ensure that the puncture needle does not fall and cause injury.

Using a Phillips #2 screwdriver, remove the two 9.0 mm screws next to the detached tube.

Hold on to the puncture needle when removing the screws to ensure that the puncture needle does not fall and cause injury.

Step 9

  • Gently pull the puncture needle down and out from the Keurig.

Gently pull the puncture needle down and out from the Keurig.

To reassemble your device, follow these instructions in reverse order.

Cancel: I did not complete this guide.

Author

                                      with 2 other contributors 

                    Steven Tran                     

Member since: 10/14/2018

329 Reputation

                                      2 Guides authored                  



                       Badges:
                       6







                                                        +3 more badges                           

Team

                       UW Tacoma, Team S1-G6, Rose Fall 2018                        

                                                  Member of UW Tacoma, Team S1-G6, Rose Fall 2018 



                    UWT-ROSE-F18S1G6                     


                                            4 Members                     


                                            5 Guides authored